Model
|
Max.
Flow
GPM
|
Max.
Head
FT
|
Max.
Temp
°F
|
Max.
Visc
SSU
|
Max.
Spec
Grav.
|
Connections
|
Wetted**
Materials
|
MOTOR DATA
|
Shp.
Wt.
Lbs
|
Overall
Dimensions
In.
|
Inlet
|
Outlet
|
HP
|
RPM
|
Volts
|
PH
|
Hz
|
Encl
|
3010-1011
|
5.8
|
30
|
180
|
50
|
1.2
|
5/8" O.D.
|
5/8" O.D.
|
PH, 6S, NE
|
Call for information on motors
and mounting components
available for use with JABSCO pumps.
|
1
|
4 X 5 X 5
|
12850-0001
|
11
|
50
|
180
|
100
|
1.5
|
1/2" FPT
|
1/2" FPT
|
PH, 6S, NE, CB, CE
|
4
|
5 X 7 X 8
|
12860-0001
|
26
|
60
|
180
|
500
|
1.7
|
1" FPT
|
1" FPT
|
PH, 6S, NE, CB, CE
|
6
|
5 X 6 X 8
|
12460-0011
|
1.7
|
30
|
180
|
50
|
1.2
|
3/8" FPT & 3/4" grdn. hose
|
3/8" FPT & 3/4" grdn. hose
|
PH, 3S, NE
|
0.024
|
1700
|
12 VDC
|
|
|
DC
|
4
|
4 X 5 X 7
|
12560-0001
|
3.7
|
20
|
180
|
50
|
1.3
|
5/8" O.D.
|
5/8" O.D.
|
PH, 3S, NE
|
0.052
|
1700
|
12 VDC
|
|
|
DC
|
5
|
4 X 5 X 6
|
12310-0001
|
4
|
50
|
180
|
50
|
1.3
|
3/8" FPT & 3/4" grdn. hose
|
3/8" FPT & 3/4" grdn. hose
|
PH, 3S, NE
|
1/12
|
1750
|
115
|
1
|
60
|
ODP
|
6
|
4 X 5 X 7
|
12290-0001
|
5.8
|
30
|
180
|
500
|
1.5
|
5/8" O.D
|
5/8" O.D
|
PH, 3S, NE
|
1/6
|
1750
|
115
|
1
|
60
|
ODP
|
12
|
6 X 8 X 19
|
17000-0001
|
5.5
|
50
|
180
|
10
|
1.2
|
3/8" FPT
|
3/8" FPT
|
EP, CB, CE, NE
|
Call for information on motors
and mounting components
available for use with JABSCO pumps.
|
4
|
5 X 5 X 8
|
17590-0001
|
11.3
|
50
|
180
|
500
|
1.5
|
1/2" FPT
|
1/2" FPT
|
EP, CB, CE, NE
|
8
|
5 X 7 X 11
|
14540-0001
|
25
|
60
|
180
|
500
|
1.7
|
1"FPT
|
1"FPT
|
EP, CB, CE, 6S, NE
|
9
|
5 X 6 X 12
|
17020-0001
|
5.5
|
50
|
180
|
500
|
1.5
|
3/8" FPT
|
3/8" FPT
|
EP, CB, CE, NE,
|
1/4
|
1750
|
115
|
1
|
60
|
TEFC
|
21
|
8 X 8 X 13
|
17430-0001
|
11
|
50
|
180
|
500
|
1.7
|
1/2" FPT
|
1/2" FPT
|
EP, CB, CE, NE,
|
1/2
|
1750
|
115
|
1
|
60
|
TEFC
|
34
|
9 X 10 X 15
|
14510-0001
|
25
|
60
|
180
|
500
|
1.7
|
1" FPT
|
1" FPT
|
EP, CB, CE, 6S, NE
|
1
|
1750
|
115
|
1
|
60
|
TEFC
|
38
|
10 X 12 X17
|
Other seal configurations available for
temperatures up to 350°F.
* Contact a Water Cooling Engineer for assistance in selecting
pumps for fluids over 500 SSU.
** Also available in All Bronze and 316SSS construction.
See page 5 for material legend.
|
Contact a Water Cooling Application Engineer for assistance
in selecting pumps for fluids with specific gravity over 1.1.
Also available in TEFC and Explosion Proof.
|
|